Do two Transceivers = Collision Domain?
DComTalk.com Forum Index DComTalk.com
Discussion of VoIP, VPN, Video Conferencen, DSL and other data commucations.
 
 FAQFAQ   MemberlistMemberlist     RegisterRegister 
 ProfileProfile   Log in to check your private messagesLog in to check your private messages   Log inLog in 
 
Google
 
Web dcomtalk.com
Do two Transceivers = Collision Domain?

 
Post new topic   Reply to topic    DComTalk.com Forum Index -> Ethernet
Author Message
Hal Kuff
Guest





Posted: Tue Jun 07, 2005 10:30 pm    Post subject: Do two Transceivers = Collision Domain? Reply with quote

To settle an old argument, do two transceivers with a cable between them
(of PHD spec lenght) constitute a valid collision domain? Years ago I was
told that was considered extremely bad practice....
Back to top
Guest






Posted: Tue Jun 07, 2005 11:10 pm    Post subject: Re: Do two Transceivers = Collision Domain? Reply with quote

"Hal Kuff" <kuff@tessco.com> wrote:
Quote:
To settle an old argument, do two transceivers with a cable between them
(of PHD spec lenght) constitute a valid collision domain?

Sure, why not? If they both talk at the same time, they'll collide.
[Well, unless they are full-duplex, but then there are no collisions,
so talking about a domain for them isn't sensical...]

Quote:
Years ago I was
told that was considered extremely bad practice....

What was? To put two transcievers on a cable? To consider that a
collision domain?

Maybe I'm missing something, what's "PHD spec lenght"?
Back to top
Hal Kuff
Guest





Posted: Wed Jun 08, 2005 12:20 am    Post subject: Re: Do two Transceivers = Collision Domain? Reply with quote

Sorry I meant PHY, that is to say the cable length would satisfy minimum
length .....Honestly, there seemed a debate occuring in past years about
whether the spec supported the use of transceivers in this manner.


<William P. N. Smith> wrote in message
news:qioba1hrgifodd1j5budr7e40049spi1b5@4ax.com...
Quote:
"Hal Kuff" <kuff@tessco.com> wrote:
To settle an old argument, do two transceivers with a cable between them
(of PHD spec lenght) constitute a valid collision domain?

Sure, why not? If they both talk at the same time, they'll collide.
[Well, unless they are full-duplex, but then there are no collisions,
so talking about a domain for them isn't sensical...]

Years ago I was
told that was considered extremely bad practice....

What was? To put two transcievers on a cable? To consider that a
collision domain?

Maybe I'm missing something, what's "PHD spec lenght"?
Back to top
Rich Seifert
Guest





Posted: Thu Jun 09, 2005 12:20 am    Post subject: Re: Do two Transceivers = Collision Domain? Reply with quote

In article <11ac90c34kvc7ea@corp.supernews.com>,
"Hal Kuff" <kuff@tessco.com> wrote:

Quote:
Sorry I meant PHY, that is to say the cable length would satisfy minimum
length .....Honestly, there seemed a debate occuring in past years about
whether the spec supported the use of transceivers in this manner.


In the case of 10/100/1000BASE-T, having only two transceivers connected
by a proper cable is the ONLY way to connect them. Unlike
10BASE2/10BASE5 (coaxial Ethernet), you cannot have more than two
transceivers connected to a given cable.

Whether those two transceivers comprise the entire collision domain or
only a portion of it is a function of the hub device (bridge/switch vs.
repeater). Remember, the hub device has an internal transceiver for each
port, and all 10/100/1000BASE-T configurations use only point-to-point
links between pairs of transceivers.


--
Rich Seifert Networks and Communications Consulting
21885 Bear Creek Way
(408) 395-5700 Los Gatos, CA 95033
(408) 228-0803 FAX

Send replies to: usenet at richseifert dot com
Back to top
Alan J. Flavell
Guest





Posted: Thu Jun 09, 2005 12:20 am    Post subject: Re: Do two Transceivers = Collision Domain? Reply with quote

On Tue, 7 Jun 2005, Hal Kuff wrote:

Quote:
To settle an old argument, do two transceivers with a cable
between them (of PHD spec lenght) constitute a valid collision
domain?

Any chance of a translation into English for native speakers?

Back in co-ax days, there was a recommended minimum distance between
nodes for proper collision resolution, if that has any relevance to
the question.
Back to top
 
Post new topic   Reply to topic    DComTalk.com Forum Index -> Ethernet All times are GMT