Leviton T568A scheme

Cabling selection, installation and use.

Leviton T568A scheme

Postby Guest » Thu Nov 17, 2005 7:43 pm

I have a leviton SMC panel which the insturctions says to use T568A.
So that means my wall outlet jacks will be wired up using the T568A
scheme.

I am also making my own patch cables, for both at the SMC and from wall
jack to computers. if I make the cables with T568B standard (straight
through) will it cause signal to be degraded at all?
Guest
 

Re: Leviton T568A scheme

Postby James Knott » Fri Nov 18, 2005 2:49 am

jeremy_ho@my-deja.com wrote:

I have a leviton SMC panel which the insturctions says to use T568A.
So that means my wall outlet jacks will be wired up using the T568A
scheme.

I am also making my own patch cables, for both at the SMC and from wall
jack to computers. if I make the cables with T568B standard (straight
through) will it cause signal to be degraded at all?

As long as you maintain proper pairing within a cable, it doesn't matter
what scheme you use. However, if you mix 568A & 568B in the same cable,
you'll wind up with a crossover.
James Knott
 