Can't get CID setting to save in USR 5686
DComTalk.com Forum Index DComTalk.com
Discussion of VoIP, VPN, Video Conferencen, DSL and other data commucations.
 
 FAQFAQ   MemberlistMemberlist     RegisterRegister 
 ProfileProfile   Log in to check your private messagesLog in to check your private messages   Log inLog in 
 
Google
 
Web dcomtalk.com
Can't get CID setting to save in USR 5686

 
Post new topic   Reply to topic    DComTalk.com Forum Index -> Modems
Author Message
Guest






Posted: Wed Oct 19, 2005 5:30 am    Post subject: Can't get CID setting to save in USR 5686 Reply with quote

I have a US Robotics external modem (model 5686 -
http://www.usr.com/support/product-template.asp?prod=5686) that I'm
trying to set up to be a fax server using Hylafax
(http://www.hylafax.org/). I finally got the distinctive ring feature
to work, but can't seem to get caller ID to work. Well, I can get it to
work, I just can't get the working state to save. I've managed to
figure out that what I want is to set "#CID" to 1, and caller id will
work. Trouble is, as soon as the modem does an ATZ, the setting is
lost:

ATZ
OK
AT#CID = 1
OK

RING A

DATE = 1018
TIME = 2021
NMBR = XXXXXXXXXX
NAME = STEENHAGEN JACO

RING A
ATZ
OK
AT#CID?
0

OK

I've tried both &W0 and &W1 (&W0 being the command I had to use to get
my distinctive ring setting to save), but as soon as the ATZ happens,
the CID setting is reset to 0:

ATZ
OK
AT#CID = 1
OK
AT&W0
OK
AT&W1
OK
AT#CID?
1

OK
ATZ
OK
AT#CID?
0

OK

So, does anybody out there know how to get this setting to save? I'm at
a loss :(
Back to top
Guest






Posted: Wed Oct 19, 2005 8:01 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

On 18 Oct 2005 17:30:20 -0700, jsteenhagen@gmail.com wrote:

Quote:
I have a US Robotics external modem (model 5686 -
http://www.usr.com/support/product-template.asp?prod=5686) that I'm
trying to set up to be a fax server using Hylafax
(http://www.hylafax.org/). I finally got the distinctive ring feature
to work, but can't seem to get caller ID to work. Well, I can get it to
work, I just can't get the working state to save. I've managed to
figure out that what I want is to set "#CID" to 1, and caller id will
work. Trouble is, as soon as the modem does an ATZ, the setting is
lost:


I've tried both &W0 and &W1 (&W0 being the command I had to use to get
my distinctive ring setting to save), but as soon as the ATZ happens,
the CID setting is reset to 0:

ATZ
OK
AT#CID = 1
OK
AT&W0
.....
ATZ
OK
AT#CID?
0

You might want to try using ATZ1 or ATZ2. ATZ might be resetting it
to a factory default. The options for Z go from 0 to 5.

Geo
Back to top
Paul Murphy
Guest





Posted: Wed Oct 19, 2005 11:49 pm    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

<jsteenhagen@gmail.com> wrote in message
news:1129681820.932303.57840@z14g2000cwz.googlegroups.com...
Quote:
I have a US Robotics external modem (model 5686 -
http://www.usr.com/support/product-template.asp?prod=5686) that I'm
trying to set up to be a fax server using Hylafax
(http://www.hylafax.org/). I finally got the distinctive ring feature
to work, but can't seem to get caller ID to work. Well, I can get it to
work, I just can't get the working state to save. I've managed to
figure out that what I want is to set "#CID" to 1, and caller id will
work. Trouble is, as soon as the modem does an ATZ, the setting is
lost:

snip

I'm not familiar with that Hylafax software but USR's Rapidcom software (or
SmithMicros Hotfax/Hotfax Message Centre) should log all the CID details on
your system. I cant understand why you want to save the "working state" - if
its just a log you need, default software supplied with the modem will
handle that. Additionally most telephony software even including basic
packages such as BVRPs Classic PhoneTools 6 will also allow you to setup a
fax on demand system.

Paul
Back to top
Moe Trin
Guest





Posted: Thu Oct 20, 2005 6:42 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

In the Usenet newsgroup comp.dcom.modems, in article
<1129681820.932303.57840@z14g2000cwz.googlegroups.com>,
jsteenhagen@gmail.com wrote:

Quote:
I have a US Robotics external modem (model 5686 -

I just can't get the working state to save. I've managed to
figure out that what I want is to set "#CID" to 1, and caller id will
work. Trouble is, as soon as the modem does an ATZ, the setting is
lost:

Did you read the manual? If you don't have one, fire up minicom, seyon,
or equal, and after setting the modem init string (minicom uses something
strange - set it to AT&F1), run the command 'at$' and look at the
results. On this old 5687, for the ATZ command, I see

Zn n=0 Dip #7 up: Yn
Dip #7 down: &F0
n=1 Reset to &W0 settings
n=2 Reset to &W1 settings
n=3 Reset to &F0 settings
n=4 Reset to &F1 settings
n=5 Reset to &F2 settings

So - what is your DIP switches set to?

Old guy
Back to top
Guest






Posted: Fri Oct 21, 2005 3:38 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

The Hylafax piece is actually of little consequence. I chose that
software because my fax server is a linux box. The real problem is that
the modem doesn't seem to be saving the CID setting. I can set it, and
while its set it will work fine, but as soon as the reset command is
issued, the modem looses that setting. I have a 33.6 USR modem that
will keep the CID setting across ATZ commands, but I can't seem to get
it to store it across power cycles. I could probably make a script that
goes out and issues an AT#CID=1 command periodically, but that seems
like it really shouldn't be necessary.
Back to top
Guest






Posted: Fri Oct 21, 2005 3:50 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

Zn n=0 Y setting determines reset
n=1 Reset to &W0 settings
n=2 Reset to &W1 settings
n=3 Reset to &F0 settings
n=4 Reset to &F1 settings
n=5 Reset to &F2 settings

And Y is 0 which is for:
Yn n=0 Next Reset to &W0 settings

Which means I should be using the W0 settings.... and the #CID setting
should be saved in W0, AFAICT. Anyway, here's my current settings as
saved if anybody's curious:
ATI4
U.S. Robotics 56K FAX EXT Settings...

B0 E1 F1 M1 Q0 V1 X4 Y0
BAUD=19200 PARITY=N WORDLEN=8
DIAL=TONE ON HOOK CID=0

&A3 &B1 &C1 &D2 &G0 &H1 &I0 &K1
&M4 &N0 &P0 &R2 &S0 &T5 &U0 &Y1

S00=000 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002
S07=060 S08=002 S09=006 S10=014 S11=070 S12=050 S13=000
S15=000 S16=000 S18=000 S19=000 S21=010 S22=017 S23=019
S25=005 S27=000 S28=008 S29=020 S30=000 S31=128 S32=002
S33=000 S34=000 S35=000 S36=014 S38=000 S39=000 S40=001
S41=001 S42=000

LAST DIALED #:

OK

FWIW, If I run AT#CID=1 and then ATI4, my CID setting in that above
display does say 1.
Back to top
Moe Trin
Guest





Posted: Sat Oct 22, 2005 5:15 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

In the Usenet newsgroup comp.dcom.modems, in article
<1129848601.849881.84820@g47g2000cwa.googlegroups.com>,
jsteenhagen@gmail.com wrote:

Quote:
Which means I should be using the W0 settings.... and the #CID setting
should be saved in W0, AFAICT.

Hopefully, you're not wacking &W0 very often - NVRAM has a limited number
of write cycles.

Quote:
Anyway, here's my current settings as
saved if anybody's curious:
ATI4

That's the current settings, what's in ATI5 (ati5) ?

Quote:
FWIW, If I run AT#CID=1 and then ATI4, my CID setting in that above
display does say 1.

Understood - 'ATI4' (ati4) is the _current_ settings.

How are you initializing the modem? I only use mine as a backup dialout,
but I explicitly set the modem when I use it. You could for example put
an "echo 'at#cid=1' > /dev/ttyS0" (or where ever your modem is hiding)
in /etc/rc.d/rc.local as that is the last boot script to run on boot.

I can't remember if USR's do it, but _some_ modems clear the buffers on
a 'ATZ', so anything appended to that command (example ATZ#CID=1) is lost
and all the modem sees is ATZ. This is another reason there are often
places for multiple init strings in GUI applications.

Old guy
Back to top
Guest






Posted: Wed Oct 26, 2005 4:20 pm    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

Honestly, I'm not doing anything special to initialize modem that I'm
aware of. When I installed linux on this box, there was no modem. I
added it about a week ago when I was trying to install hylafax. I have
another machine using a 33.6 faxmodem at work also running FC4 and
hylafax. I can send it an AT#CID=1 and it will keep it through an ATZ,
but not through a power cycle. Maybe I'll just take that modem home and
trough something in cron to turn on CID :).

ATI5
U.S. Robotics 56K FAX EXT NVRAM Settings...

Template Y0

DIAL=TONE B0 F1 M1 X4
BAUD=19200 PARITY=N WORDLEN=8

&A3 &B1 &G0 &H1 &I0 &K1 &M4 &N0
&P0 &R2 &S0 &T5 &U0 &Y1

S00=001 S02=043 S03=013 S04=010 S05=008 S06=002 S07=060
S08=002 S09=006 S10=014 S11=070 S12=050 S13=000 S15=000
S19=000 S21=010 S22=017 S23=019 S25=005 S27=000 S28=008
S29=020 S30=000 S31=128 S32=002 S33=000 S34=000 S35=000
S36=014 S38=000 S39=000 S40=001 S41=001 S42=000
Back to top
Moe Trin
Guest





Posted: Fri Oct 28, 2005 5:28 am    Post subject: Re: Can't get CID setting to save in USR 5686 Reply with quote

In the Usenet newsgroup comp.dcom.modems, in article
<1130340662.069290.142410@z14g2000cwz.googlegroups.com>,
jsteenhagen@gmail.com wrote:

Quote:
Honestly, I'm not doing anything special to initialize modem that I'm
aware of. When I installed linux on this box, there was no modem. I
added it about a week ago when I was trying to install hylafax.

I'm told hylafax is a fine program, though I'm not using it. Most
applications seem to come with default modem init strings that the
author discovered while on a _really_ bad acid trip. They generally
have nothing in common with the manufacturer's recommended string.

Quote:
I have another machine using a 33.6 faxmodem at work also running FC4
and hylafax. I can send it an AT#CID=1 and it will keep it through an
ATZ, but not through a power cycle.

I was going to say something above NVRAM, but that last phrase killed
that idea.

Quote:
ATI5
U.S. Robotics 56K FAX EXT NVRAM Settings...

Yeah, but notice the '#CID' isn't listed as part of the RAM.

My solution would be to change the modem init string. You've got
the ATI4 (ati4) settings that result from a ATZ - why not compare that
to the ATI4 (ati4) settings that result from a AT&F1 - what's different?
I'd then change the init string from ATZ to 'AT&F1#CID=1' plus what
ever else needs changing. 'ATZ#CID=1' _might_ work, but I'm not sure
how portable it may be - I do know that some unspecified modems clear
the command register on a ATZ, so the #CID=1 could be lost.

Old guy
Back to top
 
Post new topic   Reply to topic    DComTalk.com Forum Index -> Modems All times are GMT
Page 1 of 1

 
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum




VoIP Solutions: Telephone Systems Electronics Satellite TV Tech & Gadgets
Powered by phpBB